Glass Sun Protection Film
- Material: Optical-grade multi-layer PET
- Colors: Clear, neutral, smoke, blue, bronze
- Finished thickness: 25-75 um, grade-dependent
- Roll Width: Up to 1520 mm
- Roll Length: 30 m, 30.5 m or 50 m
- Applications: Architectural, commercial, and automotive glazing confirmed by grade
Heat Protect Film Company is a glass sun protection film manufacturer producing PET multi-layer solar control film for architectural, commercial and selected automotive glazing. Glass Sun Protection Film is a heat rejection window film and UV protection window film that manages solar heat gain, ultraviolet radiation, glare and visible light while preserving the required view. Available grades combine multilayer PET, a solar-control coating, an optically clear acrylic adhesive and a scratch-resistant hard coat. Final VLT, TSER, SHGC, UV rejection, visible reflectance, solar absorptance and haze are confirmed on the intended glass under agreed test conditions.
Product Overview
Glass sun protection film is a permanent solar control window film for optical and thermal management, not a removable construction film used for temporary scratch or dust protection during construction, renovation, transport or installation.
The product is offered in optional technology structures or grades, not as six independent catalog SKUs. Clear UV-Control grades emphasize UV control and higher VLT; confirm VLT, UV rejection and haze. Nano-Ceramic grades use a non-metallic ceramic structure for heat control; confirm TSER, infrared performance and signal compatibility. Reflective grades increase solar reflection; confirm visible reflectance, VLT and TSER. Dual-reflective grades manage the difference between interior and exterior reflectance. Spectrally selective and exterior-grade options, where offered, should be qualified on the actual glass for VLT, SHGC, weathering and adhesion. Only constructions already discussed for this product — coated, sputtered, metallized and non-metallic / ceramic — are referenced here. Whether a structure is offered is confirmed by grade; this page does not treat a direction as standing stock or as discontinued.
High-VLT grades suit offices, curtain walls and retail glazing where daylight and outward visibility matter. Lower-VLT grades provide stronger glare control for exposed facades and selected vehicle windows but may reduce interior brightness and nighttime visibility. Neutral films limit appearance change, while reflective grades strengthen daytime solar control.
Performance must be reviewed as a film-and-glass system. The same grade can produce different VLT, TSER, SHGC and solar absorptance on clear, tinted, tempered, laminated, Low-E or insulated glass. Check full-size samples in sun, overcast weather and evening light for color, haze, distortion, reflection and coating uniformity.
Product Photos

Applications
- Office and commercial windows exposed to strong sunlight
- Storefront and display glazing requiring UV protection
- Curtain walls and floor-to-ceiling architectural glass
- Hotels, schools, hospitals and public buildings
- Residential glazing affected by afternoon solar heat
- Automotive side windows, rear windows and sunroofs, using a grade confirmed for automotive glazing and local regulations
- Windshields only where the installed net VLT meets local regulations; architectural film is not suitable for all automotive glass, including all windshields
- Converting lines using slit solar control window film rolls

Benefits
- Reduces solar hot spots near exposed windows.
- Filters UV and helps slow UV-related fading.
- Improves screen visibility in bright interiors.
- Offers VLT grades for daylight or stronger glare control.
- Maintains clear views through low-haze PET and optical adhesive.
- Provides neutral, low-reflective and reflective appearances.
- Supports selection by VLT, TSER, SHGC, UV rejection, visible reflectance, solar absorptance and haze.
- Allows controlled slitting and repeat-batch comparison.
What Performance Data Should Be Compared When Balancing Heat Reduction, Visible Light and Glare?
Do not select PET multi-layer solar control film from infrared rejection alone. Reports may use different wavelength ranges, so a high narrow-band IR figure does not always indicate stronger overall heat control. Compare VLT, SHGC, TSER, UV rejection, interior and exterior visible reflectance, solar absorptance and haze on the same reference glass and test method. Higher VLT preserves daylight; lower SHGC generally means less incoming solar heat. Darker grades control glare more strongly but can reduce room brightness and nighttime visibility. Published figures are typical grade-dependent references and must be validated on the actual glass with the stated method and build-up.
TDS / Technical Data Sheet
Item | Typical Value |
Product type | PET glass sun protection film |
Base material | Optical-grade multi-layer PET |
Functional structure | Coated, sputtered, metallized or non-metallic, grade-dependent. Clear UV-Control, Nano-Ceramic, Reflective, Dual-Reflective, Spectrally Selective, and Exterior-Grade are optional structures or grades of this product, not separate catalog SKUs. |
PET / ply thickness | Confirm by grade. Single-ply PET thickness is recorded separately from finished thickness. |
Finished thickness | 25-75 um, typical and grade-dependent |
Visible Light Transmission (VLT) | 15%-75% on specified reference glass; typical grade-dependent reference, validate on the actual glass with the stated method |
UV Rejection | Up to 99%, grade and method dependent; confirm test waveband and method |
TSER (Total Solar Energy Rejected) | 35%-70%, film-and-glass system reference; confirm test glass and standard |
SHGC | Approx. 0.30-0.65, depending on glazing; confirm glass structure and test conditions |
Infrared Performance | Confirm by grade, wavelength range, and test method. A single-wavelength result is not overall heat-control performance. |
Visible Reflectance, interior | Confirm by grade and method. Record interior and exterior reflectance separately. |
Visible Reflectance, exterior | Confirm by grade and method. Record interior and exterior reflectance separately. |
Solar Absorptance | Confirm by grade, product structure, and the film-and-glass system |
Glare reduction | Approx. 20%-80%, mainly related to VLT; typical grade-dependent reference |
Haze | Low-haze grade available, confirm by agreed method |
Adhesive | Optically clear acrylic pressure-sensitive adhesive; confirm the adhesive system by grade |
Hard Coat | Scratch-resistant hard coat; confirm interior or exterior hard-coat structure by grade |
Test glass / standard / conditions | Film-and-glass values are typical grade-dependent references. Validate on the actual glass with the stated method, test glass, and build-up. Not a combined maximum from different grades. |
Data status | Typical grade-dependent references; validate on actual glass |
Roll width | Up to 1520 mm |
Roll length | 30 m / 30.5 m / 50 m |
Core | 3 inch paper or plastic core |
Building checks | Type, thickness, coating side, heat treatment and thermal stress |
Automotive checks | Heat shrinking, edge behavior, net VLT, haze and distortion; confirm the actual grade and local regulations. Architectural film is not claimed as suitable for all automotive glass, including all windshields. |
Production checks | Shade, coating uniformity, roll flatness and slit edges |
Retained sample | Grade, glass type, coating side, method and date |
Production Line

How Should One Solar Control Film Grade Be Qualified for Building and Automotive Glass?
Architectural testing and automotive testing are separate. For building glass, confirm pane thickness, color, heat treatment, single-pane or insulated construction, Low-E coating position, facade orientation and solar exposure. Tempered glass, laminated glass, Low-E glass and insulated glass must be qualified as a film-and-glass system. Coating position, heat treatment and absorbed solar energy can change glass temperature, so thermal-stress review should include edge condition, frame shading and local heat buildup. Do not approve a grade from film-only data.
Automotive checks must cover the intended position — side windows, back glass, sunroofs and, only where permitted, windshields. Review curved-glass heat shrinking, edge behavior, distortion, nighttime visibility, signal compatibility and installed net VLT. Compliance depends on the combined film-and-glass result and local regulations. Do not assume a building-glass grade is suitable for all automotive glass, including all windshields.
Retain the approved sample with its grade, glass type, coating side, method and date. Compare later batches for shade, haze, reflectance, coating consistency and forming behavior.
Loading Containers

FAQ
Can one glass sun protection film grade be applied to every glazing type?
No. Structure, coatings, thickness, color and heat treatment affect visible light, solar absorption and thermal behavior. Test the actual glazing before bulk production.
Does UV rejection completely prevent interior fading?
No. Visible light, heat, humidity and material stability also influence long-term color change.
What should be confirmed before roll production?
Confirm structure, thickness, VLT, width, length, core, winding direction, intended glass, coating side, installation side and test method.
Can the same PET solar control film serve buildings and vehicles?
Some structures may support both, but automotive grades require additional forming, installed-VLT, clarity, signal and regulatory checks. A film qualified for architectural glass is not automatically suitable for all automotive glass, including all windshields.