Polyester Film Thermal Conductivity Technical Data

Polyester film thermal conductivity data are meaningful only when PET grade, film thickness, heat-flow direction, temperature, and retained layers are identified. This reference covers bare BOPET and defined adhesive-coated PET constructions used in insulation, converting, and temporary surface protection. Published values can support preliminary layer-resistance calculations; coated assemblies, heated processes, and removal behavior should be confirmed with samples on the intended surface and equipment.

Category:

The Measurement Boundary

This technical data sheet covers unfilled biaxially oriented PET base films, treated PET carriers, and defined adhesive-coated constructions used for through-thickness calculations.

It does not rate solar control, flammability, melting point, or universal service temperature. Resin, thick sheet, filled, metallized, and finished laminates need structure-matched data.

Thermal conductivity describes heat flow through the tested construction. For phase-transition behavior instead of heat-flow measurement, review polyester film DSC melting data. Keep thickness, temperature, and construction details with the conductivity result.

What Is Inside the Tested Stack

A test stack may contain PET base film, surface treatment, adhesive, and liner. Every retained layer must be identified so an assembly result is not mistaken for bare PET.

Treatment on corona-treated PET film supports coating anchorage, not a conductivity value. If PET release liner constructions remain attached, their carrier, silicone layer, and interfaces add resistance. Modified grades require separate confirmation.

Data Record for the Tested Construction

Replace reference entries with tested-grade or project-confirmed data when available.

Item

Typical Value / Reference Range

Test Method or Condition

Notes

Base film

Identified industrial PET / BOPET grade

Construction record

State unfilled, treated, coated, or modified.

Film construction

Bare PET or PET + treatment + adhesive + optional liner

Layer record

List all retained test layers.

Film thickness

Project-confirmed, um

Calibrated gauge, multiple points

Report mean and range.

Total construction thickness

Project-confirmed, um

Coating-compatible gauge

Do not replace with carrier thickness.

Thermal conductivity

About 0.13-0.16 W/(m.K), unfilled BOPET reference

Through-plane near ambient; method stated

Confirm grade, direction, and temperature.

Mean test temperature

Project-confirmed

Record hot and cold surfaces

Ambient data may not predict heated use.

Calculated resistance

R'' = t/k, m2.K/W

Measured thickness and tested conductivity

Applies only to the identified layer.

Surface treatment

Untreated, corona, or chemical

Identify treated side

Match test and production specimens.

Adhesive type

Project-confirmed system

Construction record

Affects resistance and aged peel.

Peel adhesion

Sample-specific

Defined substrate, dwell, angle, speed, temperature

Not a universal removal prediction.

Tensile / elongation

Tested grade, MD and TD

ASTM D882, ISO 527-3, or equivalent

Supports handling and tear review.

Haze / transmission

Tested clear construction

ASTM D1003 or equivalent

Optical values do not determine conductivity.

Storage condition

Controlled indoor storage; intact packaging

Grade instruction

Recheck aged or exposed rolls.

Choosing the Measurement Route

When one PET layer is too thin for stable measurement, test several layer counts under identical pressure and temperature. Plot resistance against total thickness: the slope estimates material resistivity, while the intercept reflects contact effects. Report thickness, pressure, replicates, regression quality, and uncertainty.

For coated film, define whether the result represents the PET carrier or the supplied assembly; report the latter as total resistance or apparent conductivity.

Test Item

What It Checks

Suggested Method or Reference

Why It Matters

When To Request It

Through-plane conductivity

Heat across thickness

ISO 22007-2 or equivalent

Primary direction for film layers.

When heat flow affects design.

Stacked-film resistance

Resistance across layer counts

ASTM E1530-type approach

Separates thickness and contact effects.

When one layer is too thin.

In-plane conductivity

Heat along MD or TD

Validated anisotropic method

Checks orientation effects.

When lateral spreading matters.

Thickness

Carrier and coated thickness

Multipoint calibrated gauge

Captures coat and cross-web variation.

For every comparison.

Peel adhesion

Removal force after dwell

ASTM D3330, FINAT FTM 1, or equivalent

Depends on surface and settings.

For the actual coated surface.

Dwell inspection

Lifting, bubbles, trace, gloss, tearing, residue

24 h, 72 h, and 7 day comparison

Links data to surface behavior.

Before a new surface or process.

From Conductivity to Layer Resistance

Polyester film thermal conductivity is a material property; thickness creates resistance. Under unchanged grade, direction, and temperature, 100 um film has about twice the PET-layer resistance of 50 um film. Low conductivity alone does not make an ultrathin film an effective insulator.

Thickness tolerance, adhesive coat weight, liner status, and contact resistance may outweigh small differences among published values. Data for flame-retardant polyester film should not replace unfilled PET data. Mechanical and optical properties cannot substitute for thermal measurement.

Where the Same Film Gives a Different Outcome

On glass, cleanliness, coatings, sunlight, and bubbles affect results. On metal, oil, texture, forming stress, and removal temperature matter. For electrical insulation PET film, review conductivity with dielectric needs, operating temperature, thickness, and the assembled heat-flow path.

Plastics differ in surface energy and additive migration. Painted surfaces need confirmed cure; rough surfaces trap air; low-energy surfaces may provide weak holding force.

Evidence from 24 h, 72 h and 7 Day Checks

Apply a representative sample using intended pressure or equipment settings. Record substrate, coating, temperature, humidity, orientation, and removal direction.

At 24 h, inspect peel, bubbles, distortion, and edge lifting. At 72 h, check adhesion build, trace, surface shadow, and gloss. At 7 days, check difficult removal, tearing, transfer, discoloration, coating interaction, and residue. Cool heated samples under intended conditions before removal.

Project samples may use verified film coating, slitting and quality-control capabilities, but records must identify the actual equipment or laboratory. Repeat testing when the surface, temperature, storage history, equipment, or operator changes.

Failure Signals Hidden by a Single Data Point

The table links data shifts to process symptoms and verification.

Data Point

If Too Low

If Too High

Risk in Application

Check Before Full Use

Film thickness

Understates resistance; raises tear risk.

Raises resistance or stiffness.

Wrong heat estimate or handling.

Measure the actual roll.

Thermal conductivity

Slower heat flow than calculated.

Faster heat flow than calculated.

Wrong temperature or process time.

Test grade, direction, and temperature.

Peel adhesion

Lifting or poor wet-out.

Difficult removal or trace.

Protection failure or rework.

Run staged peel checks.

Tensile / elongation

Splitting or low strain tolerance.

Stiffness, necking, or unstable peel.

Web break or incomplete removal.

Test MD and TD under intended tension.

Surface treatment

Poor coating or adhesive anchorage.

Aged or excessive treatment inconsistency.

Delamination or uneven peel.

Identify side; confirm surface energy.

Storage age / exposure

Performance below tested state.

Adhesion or optical change rises.

Lab-to-production mismatch.

Repeat peel, edge, and optical checks.

Keeping the Reference Roll Comparable

Store rolls in intact packaging indoors, away from sunlight, moisture, condensation, dust, and heat. Prevent flattening, telescoping, core damage, and marked outer layers.

Long storage, hot transport, temperature cycling, or packaging damage can alter results. Equilibrate rolls before opening and repeat peel, edge, and residue checks after abnormal exposure.

Questions Raised During Technical Review

What is a typical polyester film thermal conductivity value?

Published values for unfilled BOPET are commonly about 0.13-0.16 W/(m.K) near ambient temperature. Treat this as a reference unless grade, direction, temperature, and method match.

Does thickness change conductivity or thermal resistance?

For a uniform grade, thickness changes layer resistance, not intrinsic conductivity. Coatings, interfaces, orientation, additives, and temperature can change the assembly result.

Can bare PET data be used for adhesive-coated protective film?

Only for a preliminary PET-layer estimate. Adhesive, treatment, liner, air gaps, and interfaces require validation of the complete construction.

Why are 24 h, 72 h, and 7 day checks necessary?

Adhesion develops over time. Staged checks reveal lifting, bubbles, trace, gloss change, difficult removal, tearing, or residue not visible immediately.